We perform non-destructive tests of key component cracks: by the magnetic method (MPI) for magnetic materials, and penetration method (FPI) for non-magnetic materials. Both test methods have been NADCAP certified since 2011.
Specifications
Fluorescent penetrant inspection (FPI)
- Detection sensitivity IA3a
- Penetrant ARDROX 970P25E
- Developer ARDROX 9D4A
- Maximum component length: 700 mm
- Maximum component weight 30 kg
Magnetic particle inspection (MPI)
- Three-phase power: FWDC 600A, AC 3500 A
- Magnetisation in 1.0 sec
- Maximum component length 1 200 mm
- Maximum component weight: 200 kg