NON-DESTRUCTIVE TESTS

We perform non-destructive tests of key component cracks: by the magnetic method (MPI) for magnetic materials, and penetration method (FPI) for non-magnetic materials. Both test methods have been NADCAP certified since 2011.

Specifications 

Fluorescent penetrant inspection (FPI)

  • Detection sensitivity IA3a
  • Penetrant ARDROX 970P25E
  • Developer ARDROX 9D4A
  • Maximum component length: 700 mm
  • Maximum component weight 30 kg

Magnetic particle inspection (MPI)

  • Three-phase power: FWDC 600A, AC 3500 A
  • Magnetisation in 1.0 sec
  • Maximum component length 1 200 mm
  • Maximum component weight: 200 kg